LY-A4V Series Axial Piston Variable Displacement Pump--Technical Data

Operating Pressure Range_____Inlet
 Variable Pump
 Boost Pressure Pbo________2.5MPa
 Auxiliary Pump
 Suction Pressure Psmin(V≤30mm2/s)≥0.08MPa(Absolute)
   When Cold Start     ≥0.05MPa(Absolute)
Case Drain Pressure
 Port T1、T2 Or T3 And T4 Permissible Pressure
 PL         0.2MPa (Absolute)
 Short Term(At Start)    0.3MPa (Absolute)
Size Calculation

Operating Pressure Range ____Outlet
 Variable Pump
 Port A Or B Rated Pressure ____40MPa
 (Max.)Pressure Pmax____________45MPa
 Auxiliary Pump
 Rated Pressure Pb_____________2.5MPa
 Peak Pressure Prmax__________4.0MPa
Mounting Position
 Optional:Pump housing must be filled with fluid.
Flow Direction
 Rotation,please refer to the below sheet of each control detail for the relation between control and the direction of flow.
Filtration
 Boost pump in suction line filtration (Equipped Auxiliary Pump)
 Would better use standard type filter.
 Resistance to flow at the filter element:
 V=30mm2/s, n=nmax___ΔP≤0.01MPa
 V=103mm2/s,n=103r/min,ΔP≤0.03MPa
Pressure for auxiliary pump suction S
 V=30mm2/s____________ΔP≥0.08MPa
 When cold start______ΔP≥0.05MPa
 Filter don't apply with side path valve,better with resistance indicator filtration.

Boost pump in pressure line filtration (Equipped Auxiliary Pump)
 Mounting Of Filter:
 The rated size of the hole in the filter is 10um regardless of the filter fitting separate in the pressureLine or fitting direct in the variable pump.
 Resistance to flow at the filter element:
 V=30mm2/s ____________ ΔP≤0.1MPa
 When cold start ________ΔPmax≤0.3MPa
     (Valid nmin~nmax entire speed range)
 It is better for filter to apply with side-path valve,if so,please also apply with a resistance indicator.
 When ordering,please note the details of the resistance indicator clearly.If a fiter is required to fit in the Variable pump.
 Example:Voltage 12V or 24V
    Direct or direct/ Voltage (12V or 24V)